ATMOS          EKO     Orlan
Red Super, EKO and ATMOS wood        
            gasification Boilers

High Efficiency (87-91 %)
Easy and simple service
Fuel loadings - once every  8 -12 hours
Boilers range: 18 - 80 kW  (61,000 btu - 275,000 btu)
Boiler power modulation from 40 - 100 % (variable output)
Small quantity of ash
Orlan has electronic regulator with temperature sensors built in
Low cost
Nature friendly
Made from boiler plate steel
Efficient
Cost effective
Easy to maintain
Why it
Orlan Ceramics in upper load
chamber
Orlan Ceramics in lower chamber
Lower Chamber, "S" model
Atmos DC 25S               Atmos DC 25GS
Lower Chamber, "gs" model
Atmos Upper Load Chamber,
"gs" model
Atmos Upper Load Chamber,
"S" model
"gs" model
"s" model
An attractive exchange rate allows us to offer
the high quality Orlan and ATMOS boilers at a
competitive price.
Atmos wood gasification boilers are high quality boilers made of
3-8 mm thick boiler plate steel.
Atmos offers two lines of wood gasification boilers, the "S" and "GS".
The difference between them is the amount of ceramic and the combustion air path.
Boiler temperature and output is regulated by a draft regulator.
The fan draws the exhaust out of the burn chambers, therefore creating a negative
pressure in the firebox, reducing the smoke that is let out into the room, when
loading.
ATMOS Boilers
Red Super and Orlan EKO boilers are equipped with the
RK 2001U regulator enabling:
Interaction with circulating pump
Interaction with room temperature sensor, installed in mostly used room
Modulation of fan rotation
Boiler temp. to 195 degrees f.
Interaction with room thermostat
Gasification process in wood fired boilers is divided into 4 stages:

Drying and release of wood gases inside the loading chamber in slow
glowing process

Burning of gas mixture with secondary air in the lower chamber at over
2000 deg. F.

Flame reheating and heat exchange

Combustion gases ejecting through chimney pipe. The best indicator of
successful wood gasification is the lack of smoke exiting the chimney.
Heat exchanger cleaner and bypass leaver
Orlan EKO and Red Super 60 Heat
exchanger, turbulators and bypass flap
Brochures and installation Manuals
Brochures and installation Manuals
Neither the Orlan nor the ATMOS wood boilers are UL
approved, they are CE and/or TUV, this is roughly
equivalent, but, you will want to check with your building
department as to whether they will accept this
certification.